PanelView Plus · FactoryTalk View ME · SoCal

PanelView Plus Contractor
Southern California

PanelView Classic 550, 600, 900, and 1000 series terminals communicate via DH-485 or serial — protocols that are end-of-life along with the PLCs they connect to. PanelView Plus replacement is usually part of a larger PLC migration, but sometimes it is the right standalone project.

Fixed-price proposals
On-site SoCal
Studio 5000 certified

Request a Quote

Same-day response. Describe your project — we’ll schedule a walkdown and deliver a proposal.

The Service

PanelView Plus Contractor — Southern California

Direct Source installs and programs Allen-Bradley PanelView Plus 6 and 7 terminals for manufacturing and industrial facilities across Southern California. New installations, PanelView Classic replacements, FactoryTalk View ME application development, EtherNet/IP configuration, and operator training. Standalone projects and as part of larger PLC migration projects.

PanelView Plus 7 Installation

PanelView Plus 7 terminal mounting, EtherNet/IP network connection, FactoryTalk View ME runtime installation, and application load — ready for operator use. Panel cutout modification if replacing a different terminal size.

Physical installation is the easy part — application configuration is where the work is.

FactoryTalk View ME Application

FTV ME screen design: navigation structure, process graphic displays, trend displays, alarm summary, recipe management screens, and security configuration for operator and maintenance access levels.

We design screens for the operators who use them — clear, logical navigation, consistent graphic conventions.

EtherNet/IP Tag Configuration

ControlLogix and CompactLogix EtherNet/IP tag binding in FTV ME: tag import from Studio 5000, tag browser configuration, and connection to multiple ControlLogix controllers from one PanelView Plus terminal.

Tag binding errors are the most common source of PanelView startup problems — we verify every tag.

PanelView Classic Replacement

PanelView 550, 600, 900, and 1000 replacement with PanelView Plus 7. DH-485 or serial to EtherNet/IP communication change, application recreation in FTV ME, and screen layout migration to the new terminal.

Screen layouts are recreated for the new terminal’s resolution — not just scaled up from the old terminal’s smaller screen.

Alarm Configuration

FTV ME alarm configuration: alarm triggers linked to ControlLogix tags, alarm messages, severity indicators, alarm history display, and operator acknowledgment configuration.

Alarm configuration directly affects how fast operators respond to process problems.

Operator Training

On-site operator training for new PanelView Plus applications: navigation, alarm acknowledgment, recipe selection, and basic troubleshooting. Training delivered at your facility with your operators on the actual installed terminal.

Operators who understand the HMI use it more effectively — we include training in every new installation.

Why Direct Source

What Makes Our Approach Different

Screen design for operators

HMI screens designed for operator usability: clear navigation, process-relevant graphics, and alarm displays that communicate what operators need to know. Not just technically correct — actually useful on the production floor.

PanelView Classic migration experience

PanelView 550/600/900/1000 to PanelView Plus 7 replacements. DH-485 to EtherNet/IP, application recreation, and panel modification for new terminal size.

Standalone or as part of PLC migration

PanelView Plus projects as standalone replacements or integrated into SLC-500, PLC-5, or MicroLogix migration projects. Whatever your project structure requires.

Southern California coverage

Los Angeles, Orange County, Inland Empire. On-site for all phases of PanelView Plus projects.

Every Project Includes

  • PanelView Plus 7 installation
  • FTV ME application development
  • EtherNet/IP tag configuration
  • Alarm configuration
  • On-site startup & verification
  • Operator training

Serving: Los Angeles, Orange County, Inland Empire, Long Beach, Vernon, Anaheim, Ontario, and all Southern California industrial facilities.

FAQ

Frequently Asked Questions

What is the difference between PanelView Plus 6 and PanelView Plus 7?

PanelView Plus 7 is the current Allen-Bradley HMI terminal product line, replacing the PanelView Plus 6. The 7 series has faster processors, improved displays, USB and SD card support, and runs the current FactoryTalk View ME 13 and later. Both use EtherNet/IP to communicate with ControlLogix and CompactLogix. PanelView Plus 6 is still supported but new installations should use PanelView Plus 7.

Can you replace our PanelView 550 or 600 with a PanelView Plus?

Yes. The PanelView 550 and 600 use DH-485 communication to SLC-500 PLCs. PanelView Plus uses EtherNet/IP to ControlLogix and CompactLogix. The replacement involves a PLC migration (DH-485 to EtherNet/IP) and application recreation in FactoryTalk View ME. If you are already on ControlLogix, replacing a legacy PanelView Classic is a simpler project.

How long does a PanelView Plus screen application take to develop?

A typical machine HMI with 10–20 screens, alarm display, and trend pages takes 2–5 days of programming. Larger supervisory applications with more screens, recipes, and historian connections take longer. We provide time estimates after reviewing your screen requirements.

Can you configure the PanelView Plus to connect to multiple PLCs?

Yes. A single PanelView Plus terminal can connect to multiple ControlLogix and CompactLogix controllers via EtherNet/IP, each with its own tag database in FTV ME. This is common in packaging lines with multiple machine PLCs that share a single operator interface.

What does PanelView Plus installation and programming cost?

PanelView Plus projects in Southern California typically range from $3,000 to $15,000 depending on screen count, tag complexity, and alarm scope. PanelView Classic replacements add panel modification cost. Fixed-price proposals after reviewing your screen requirements.

Get Started

Request a Project Quote

  • Fixed-price proposal
  • On-site throughout the project
  • All hardware sourcing coordinated
  • Full documentation at completion

Call (562) 396-9924

Tell Us About Your Project

We respond same day.

Ready to Get Started?

Fixed-price proposal. On-site Southern California. Call or submit the form — we respond same day.