MicroLogix → CompactLogix · SBD

MicroLogix to CompactLogix Upgrade
San Bernardino County

MicroLogix 1000, 1100, 1200, and 1400 controllers are end-of-life. CompactLogix gives you EtherNet/IP, scalable I/O, Studio 5000 programming, and a supported platform with a long future. Direct Source handles the upgrade for San Bernardino County facilities — program migration, I/O expansion, and startup.

Fixed-price proposals
Studio 5000 certified
On-site SBD

Request a Quote

Same-day response. Describe your project — we’ll schedule a walkdown and deliver a fixed-price proposal.

The Project

MicroLogix to CompactLogix — San Bernardino County

MicroLogix controllers are common on standalone machines, small process skids, and legacy packaging equipment throughout San Bernardino County (San Bernardino, Ontario, Fontana, Rancho Cucamonga, Rialto). When they fail or approach end-of-life, CompactLogix is the right replacement: compact, scalable, EtherNet/IP native, and programmed in Studio 5000. Direct Source handles the full migration — program conversion, I/O adaptation, panel work, and startup.

Program Migration

MicroLogix RSLogix 500 program converted to Studio 5000 for CompactLogix. All rungs, timers, counters, and I/O references reviewed and updated for the new platform.

Most MicroLogix programs are straightforward to migrate — we verify every rung before startup.

I/O Adaptation

MicroLogix I/O documented and mapped to CompactLogix 5069 or 1769 I/O modules. Existing field wiring connected to new terminal blocks — field wiring reused wherever possible to minimize cost.

CompactLogix I/O is modular and scalable — you can add I/O capacity as equipment grows.

EtherNet/IP Integration

MicroLogix RS-232 and DH-485 communication replaced with EtherNet/IP. New HMI communication, SCADA connection, and remote I/O on standard EtherNet/IP infrastructure.

EtherNet/IP simplifies network maintenance and enables remote monitoring.

Panel Modification

Control panel updated to mount CompactLogix hardware. Power supply, controller, and I/O modules installed in existing panel where space allows, or new panel provided.

CompactLogix has a smaller footprint than MicroLogix in most configurations — panel modifications are typically minor.

HMI Update

PanelView Component and 550/600 HMIs replaced with PanelView Plus or FactoryTalk View ME. Tag migration and screen rebuild included. Operator interface kept familiar where possible.

HMI migration is recommended at the same time to avoid a second planned outage.

Startup & Commissioning

Full I/O checkout, program verification, machine run-through, and production confirmation. As-built documentation delivered at project close.

We stay through production verification — not just first power-on.

Why Direct Source

What Makes Our Approach Different

Fixed-price upgrades

MicroLogix to CompactLogix upgrades are well-scoped projects. We price them as fixed-price work after a site walkdown and program review.

Small machine expertise

Most MicroLogix systems run standalone machines with local I/O and a simple HMI. We understand that scope and plan for minimal machine downtime.

Studio 5000 certified

Our engineers program in Studio 5000. Program quality and documentation meet the same standards as a new machine build.

On-site in San Bernardino County

Direct Source serves San Bernardino, Ontario, Fontana, Rancho Cucamonga, Rialto for MicroLogix to CompactLogix upgrade projects.

Every Project Includes

  • Site walkdown and program review
  • Fixed-price project proposal
  • Program conversion to Studio 5000
  • I/O adaptation and panel work
  • Startup and production verification
  • As-built documentation

Serving: San Bernardino, Ontario, Fontana, Rancho Cucamonga, Rialto and surrounding cities.

FAQ

Frequently Asked Questions

Which MicroLogix models do you replace?

We replace MicroLogix 1000, 1100, 1200, and 1400. All are end-of-life and some are already past Rockwell’s last buy date. Replacement programs are available for each model.

Why upgrade to CompactLogix specifically?

CompactLogix is the natural successor to MicroLogix. It uses the same Rockwell ecosystem, programs in Studio 5000 (the same environment as ControlLogix), supports EtherNet/IP natively, and has modular scalable I/O. It’s also a current, actively supported platform with a long future ahead.

How long does a MicroLogix to CompactLogix upgrade take?

Most single-machine upgrades take 2–4 weeks from project start to production startup: 1 week for program conversion and hardware procurement, and 1–2 days for installation and startup. Larger systems with multiple controllers take longer.

Can we keep our existing HMI?

PanelView Component and PanelView 550/600 HMIs can sometimes be kept with new communication configuration. In most cases, HMI replacement at the same time is recommended to avoid a second outage and because those HMIs are also approaching end-of-life.

What does a MicroLogix upgrade cost in San Bernardino County?

MicroLogix to CompactLogix upgrades typically range from $8,000 to $40,000 depending on I/O count, HMI scope, and panel modification requirements. Fixed-price proposals delivered after a site walkdown and program review.

Get Started

Request a Project Quote

  • Fixed-price proposal after site walkdown
  • On-site throughout the project
  • All hardware sourcing coordinated
  • Full documentation at completion

Call (562) 396-9924

Tell Us About Your Project

We respond same day.

Ready to Upgrade to CompactLogix?

Fixed-price proposal. On-site San Bernardino County. Call or submit the form — we respond same day.