Legacy PLC Migration · Allen-Bradley · SBD

Allen-Bradley Legacy PLC Migration
San Bernardino County

SLC-500, PLC-5, and MicroLogix are all past end-of-life. Every day on legacy hardware is a day closer to a parts-unavailable failure. Direct Source migrates San Bernardino County facilities off end-of-life Allen-Bradley platforms to modern ControlLogix and CompactLogix — with fixed-price proposals and minimal downtime planning.

SLC-500, PLC-5, MicroLogix
Fixed-price proposals
On-site SBD

Request a Quote

Same-day response. Describe your project — we’ll schedule a walkdown and deliver a fixed-price proposal.

The Project

Legacy PLC Migration — San Bernardino County

Facilities across San Bernardino County (San Bernardino, Ontario, Fontana, Rancho Cucamonga, Rialto) are running logistics, food manufacturing, plastics, and light industrial operations on SLC-500, PLC-5, and MicroLogix systems that are past their end-of-life dates. Direct Source assesses your legacy Allen-Bradley hardware, develops a migration plan, and executes the migration to ControlLogix or CompactLogix with a planned cutover and minimal production impact.

Legacy System Assessment

On-site assessment of your SLC-500, PLC-5, or MicroLogix system: processor and I/O inventory, program documentation, network connections, HMI inventory, and failure risk evaluation. Written assessment delivered.

Assessment gives you a clear picture of what you have and what migration entails before you commit.

Program Conversion

Legacy PLC program converted to Studio 5000 for ControlLogix or CompactLogix. All rungs, I/O, data tables, PID blocks, and subroutines reviewed and adapted for the new platform.

We review every converted rung before startup. Conversion tools assist — they don’t replace review.

Hardware Migration

I/O documented and mapped to new ControlLogix or CompactLogix hardware. Existing field wiring reused wherever possible. New chassis, power supply, processor, and I/O modules specified and procured.

Field wiring reuse is evaluated during assessment and included in the fixed-price proposal.

Network Modernization

Legacy communication networks (DH+, DH-485, RS-232) replaced with EtherNet/IP. New managed switch infrastructure, updated HMI communication, and SCADA connectivity on modern EtherNet/IP.

Eliminating legacy networks removes a significant ongoing maintenance burden.

HMI Migration

Legacy HMIs migrated to current PanelView Plus or FactoryTalk View ME/SE. Tag remapping, screen rebuild, and communication reconfiguration included. Recommended at the same time as PLC migration.

Legacy HMIs are often on the same end-of-life timeline as the PLC — migrate together to avoid a second outage.

Startup & Documentation

Full I/O checkout, sequence verification, and production confirmation. As-built documentation package: panel drawings, I/O list, program printout, network configuration, and startup checklist.

Documentation is included in every migration — not an add-on.

Why Direct Source

What Makes Our Approach Different

Fixed-price migration projects

We scope legacy PLC migrations as fixed-price work. You approve the budget before the project starts.

All three legacy platforms

We migrate SLC-500, PLC-5, and MicroLogix. Most controls contractors specialize in one — we handle all three.

Planned cutover approach

Program conversion, hardware procurement, and staging happen before the cutover window. We plan for one clean cutover — not an extended unplanned outage.

On-site in San Bernardino County

Direct Source serves San Bernardino, Ontario, Fontana, Rancho Cucamonga, Rialto for Allen-Bradley legacy PLC migration projects.

Every Project Includes

  • On-site legacy system assessment
  • Fixed-price migration proposal
  • Program conversion — all rungs reviewed
  • Hardware migration and panel work
  • Network modernization to EtherNet/IP
  • As-built documentation package

Serving: San Bernardino, Ontario, Fontana, Rancho Cucamonga, Rialto and surrounding cities.

FAQ

Frequently Asked Questions

Which legacy platforms do you migrate?

We migrate Allen-Bradley SLC-500, PLC-5, and MicroLogix (1000, 1100, 1200, 1400) to ControlLogix and CompactLogix. All three are past Rockwell’s end-of-life dates.

Should we migrate now or wait until something fails?

Planned migration is significantly less expensive than emergency replacement after a failure. Planned migration allows program pre-conversion, hardware pre-staging, and a scheduled cutover window. Emergency replacement means an unplanned outage, premium-priced secondary market parts, and a rushed startup.

How do you handle undocumented legacy programs?

Many legacy PLC programs were never fully documented. Our conversion process starts with a thorough program analysis — we document what the program does before converting it, so we understand the logic and can verify the conversion is correct.

Do you handle the hardware procurement?

Yes. We specify the hardware, coordinate procurement through Rockwell distributors or direct, and stage it before the cutover. You don’t need to manage hardware logistics.

What does legacy PLC migration cost in San Bernardino County?

Legacy PLC migration costs in San Bernardino County vary by platform and scope. SLC-500 migrations typically range from $30,000 to $150,000. PLC-5 replacements are larger projects, ranging from $40,000 to $200,000. MicroLogix upgrades are smaller, typically $8,000 to $40,000. Fixed-price proposals after site walkdown.

Get Started

Request a Project Quote

  • Fixed-price proposal after site walkdown
  • On-site throughout the project
  • All hardware sourcing coordinated
  • Full documentation at completion

Call (562) 396-9924

Tell Us About Your Project

We respond same day.

Ready to Migrate Off Legacy PLCs?

Fixed-price proposal. On-site San Bernardino County. Call or submit the form — we respond same day.