GuardLogix Safety PLC
Southern California
Machine safety and process safety systems that use GuardLogix (the safety-rated ControlLogix) must be designed, programmed, and verified correctly — not just wired up and hoped to work. A safety system that fails to function on demand is worse than no safety system at all.
On-site SoCal
Studio 5000 certified
Request a Quote
Same-day response. Describe your project — we’ll schedule a walkdown and deliver a proposal.
The Service
GuardLogix Safety PLC — Southern California
Direct Source designs, installs, and commissions Allen-Bradley GuardLogix safety PLC systems for machine safety and process safety applications across Southern California. Safety I/O wiring, safety ladder and function block programming in Studio 5000 Safety, SIL verification support, ISO 13849 PL verification support, and functional safety testing. We treat safety systems with the rigor they require.
GuardLogix System Design
GuardLogix processor selection, safety I/O module selection, safety network configuration (EtherNet/IP CIP Safety), and safety system architecture design to meet your SIL or Performance Level (PL) target.
The architecture determines what SIL is achievable — hardware selection alone does not guarantee it.
Safety Program Development
Safety ladder and function block programming in Studio 5000 Safety: E-stop circuits, safety gate monitoring, light curtain and scanner integration, two-hand control, muting logic, and process safety shutdown logic.
Safety program logic is reviewed against the safety requirements specification before testing — not written and tested simultaneously.
Safety I/O Wiring & Installation
1791DS and 1732DS safety I/O wiring for guarded machines: dual-channel safety inputs, safety output wiring for contactors and drives, CIP Safety network configuration, and wiring verification testing.
Dual-channel safety wiring requires specific installation practices — single faults must not defeat the safety function.
Kinetix Safe Motion Integration
GuardLogix integration with Kinetix 5700 safe motion: STO, SS1, SLS, and SDI configuration via CIP Safety on EtherNet/IP. Safety function testing for each axis in the motion system.
Safe motion integration requires both GuardLogix and Kinetix expertise — we have both.
Functional Safety Testing
Systematic functional safety testing: each safety function tested for correct response on demand, with test records documenting test method, expected result, and actual result. Documentation structured to support your SIL/PL verification.
Testing every safety function on a real machine is non-negotiable — simulation is not sufficient.
SIL & PL Verification Support
We provide the engineering documentation your functional safety assessment needs: safety I/O list, safety logic description, wiring verification records, and functional test records. SIL/PL calculation and formal verification is coordinated with your functional safety engineer.
We provide the engineering content — formal SIL/PL certification requires a qualified functional safety engineer.
Why Direct Source
What Makes Our Approach Different
Safety systems require specific rigor
GuardLogix programming is not the same as standard ControlLogix programming. Safety task rules, safety I/O configuration, CIP Safety network requirements, and functional testing requirements are different. We know the differences.
We test every safety function
Every safety function is tested for correct response on demand — not configured and assumed to work. Test records are produced for each function. We do not sign off on a safety system without documented functional testing.
Machine safety and process safety
Guarded machinery (E-stops, gates, light curtains, two-hand control) and process safety (ESD, high-level shutdown, fire and gas integration). Both require GuardLogix and both require correct design and verification.
Southern California coverage
Los Angeles, Orange County, Inland Empire. On-site for all phases of GuardLogix projects.
Every Project Includes
- Safety system architecture design
- Safety I/O wiring (dual-channel)
- Safety program in Studio 5000 Safety
- Functional safety testing with records
- SIL/PL documentation support
- CIP Safety network configuration
Serving: Los Angeles, Orange County, Inland Empire, Long Beach, Vernon, Anaheim, Ontario, and all Southern California manufacturing and process markets.
FAQ
Frequently Asked Questions
What is the difference between GuardLogix and standard ControlLogix?
GuardLogix is a safety-rated ControlLogix variant — it uses a dual-processor architecture (standard + safety co-processor) that achieves SIL 2/SIL 3 (IEC 62061) and PLd/PLe (ISO 13849) ratings. It runs a separate Safety task in Studio 5000 that executes safety logic with restrictions on what instructions and I/O types can be used. Safety I/O uses CIP Safety protocol. Standard ControlLogix cannot be used for SIL-rated safety functions.
What safety I/O does GuardLogix support?
GuardLogix supports Allen-Bradley 1791DS and 1734-IB8S/OB8S (POINT Guard I/O) safety I/O modules, as well as CIP Safety devices from Rockwell and third parties. Safety inputs must be dual-channel for SIL 2 applications. Safety outputs use solid-state or relay safety output modules.
Can you integrate GuardLogix with our existing ControlLogix program?
Yes. GuardLogix runs a Safety task alongside the standard Logix tasks. The safety program and standard program can exchange data through a defined cross-task data exchange mechanism. We configure both the safety and standard program integration.
Do you do SIL calculations and formal functional safety certification?
We provide the engineering documentation that a SIL/PL verification requires: system architecture, safety I/O list, safety logic description, wiring verification records, and functional test records. Formal SIL calculation, PFD/PFH determination, and safety certificate issuance requires a qualified functional safety engineer (TÜV or equivalent) — we coordinate with your functional safety engineering resource or can recommend one.
What does GuardLogix installation cost in Southern California?
GuardLogix projects range from $15,000 for a single-machine safety retrofit to $150,000 or more for large process safety systems. Cost depends on I/O count, safety function count, motion safety scope, and testing requirements. Fixed-price proposals after safety requirements review.
Get Started
Request a Project Quote
- Fixed-price proposal
- On-site throughout the project
- All hardware sourcing coordinated
- Full documentation at completion
Tell Us About Your Project
We respond same day.
Ready to Get Started?
Fixed-price proposal. On-site Southern California. Call or submit the form — we respond same day.