Motor Control Center Upgrade
Southern California
An MCC upgrade is not just replacing old equipment — it is an opportunity to add VFD control, arc flash mitigation, and network connectivity that your existing MCC cannot support.
On-site SoCal
Studio 5000 certified
Request a Quote
Same-day response. Describe your project — we’ll schedule a walkdown and deliver a fixed-price proposal.
The Project
Motor Control Center Upgrade
Direct Source designs and installs motor control center upgrades for manufacturing, food processing, cold storage, and industrial facilities across Southern California. We upgrade aging MCCs to current Allen-Bradley Bulletin 2100 hardware with VFD integration, EtherNet/IP connectivity, arc flash mitigation, and modern protection coordination.
VFD Integration into MCC
Allen-Bradley PowerFlex VFDs integrated into the MCC lineup — new drive buckets, harmonic mitigation, input fusing, bypass contactors, and EtherNet/IP communication to the plant network or PLC.
MCC-mounted VFDs are cleaner and more maintainable than standalone enclosures mounted on the wall.
Arc Flash Reduction Upgrade
Current-limiting fuse upgrade, zone-selective interlocking, maintenance mode switches, and arc flash incident energy reduction modifications — reducing arc flash hazard at the MCC from higher PPE categories to lower ones.
Arc flash reduction in an existing MCC can eliminate the need for Level 4 PPE for routine maintenance.
Smart MCC & EtherNet/IP
Communication module installation in existing MCC buckets — DeviceNet to EtherNet/IP migration, smart overload relay installation, and MCC connectivity to plant network for remote monitoring and diagnostics.
Smart MCC connectivity allows remote monitoring of starter and drive status without opening the door.
Bucket & Component Modernization
Replace aging contactor and overload relay combinations with current Allen-Bradley Bulletin 500 contactors, E300 electronic overload relays, and current-limiting fuse coordination.
Electronic overload relays provide better motor protection and remote trip reporting compared to thermal bimetal types.
Infrared Thermography Survey
Thermal imaging of energized MCC bus, connections, and buckets before and after upgrade to identify hot spots, verify connection quality, and document baseline condition of the new installation.
Thermal imaging of a new installation catches installation errors — loose connections, incorrect torque — before they cause failures.
Full Project Documentation
Updated single-line diagram, MCC bucket schedule, protection coordination study update, arc flash label update, startup test records, and as-built drawings delivered at project completion.
Documentation is included in the project scope — not billed separately.
Why Direct Source
What Makes Our Approach Different
Upgrade what you have, replace what you must
We assess the existing MCC structure before recommending full replacement. If the bus, structure, and wiring are sound, an upgrade is often $50,000–$150,000 less than full replacement. We recommend what actually makes sense.
VFD integration expertise
VFD integration into an existing MCC requires harmonic analysis, proper fusing, bypass design, and EtherNet/IP configuration. We do all of it — we do not subcontract the drive work.
Southern California coverage
LA Basin, Orange County, Inland Empire — we serve industrial facilities across all three SoCal markets for MCC upgrade and replacement projects.
One contractor, complete project
Engineering, procurement, installation, startup, and documentation — one contractor managing the full scope. Upgrades do not go sideways when one team is responsible for the complete project.
Every Project Includes
- Site walkdown before proposal
- Fixed-price project proposal
- Hardware specification & procurement coordination
- On-site installation and startup
- As-built documentation package
- Post-startup support
Serving: Los Angeles, Vernon, Long Beach, Orange County, Anaheim, Ontario, Rancho Cucamonga, and all Southern California industrial markets.
FAQ
Frequently Asked Questions
Should I upgrade my existing MCC or replace it?
The right answer depends on the condition of the existing MCC’s structure, bus, and wiring. If the bus is corroded, the structure is damaged, or the lineup is so old that replacement buckets are unavailable, replacement is usually better. If the structure is sound and individual components are the problem, upgrade is often significantly less expensive. We assess this during a site walkdown.
Can you add VFDs to an existing Allen-Bradley MCC?
Yes. We install Allen-Bradley PowerFlex VFD buckets into existing Bulletin 2100 MCC lineups. This requires verifying bus capacity, specifying the correct drive bucket size, addressing harmonic loading, and configuring EtherNet/IP communication. We handle all of it.
What is zone-selective interlocking and does it reduce arc flash hazard?
Zone-selective interlocking (ZSI) is a communication scheme between overcurrent protective devices that allows faster fault clearing when a fault is detected in a protected zone. Faster fault clearing reduces arc flash incident energy — sometimes by a significant factor. It is one of several arc flash reduction methods we evaluate for MCC upgrades.
What areas of Southern California do you serve for MCC upgrades?
We serve industrial facilities across the LA Basin (Vernon, City of Industry, Long Beach, Torrance, Carson), Orange County (Anaheim, Santa Ana, Irvine), and the Inland Empire (Ontario, Rancho Cucamonga, Chino). We also travel to Ventura County and San Diego on project basis.
How do I get a quote for an MCC upgrade?
Call (562) 396-9924 or submit the form on this page. We schedule a site walkdown, review the existing MCC and motor list, and deliver a fixed-price proposal within one week of the walkdown.
Get Started
Request a Project Quote
- Fixed-price proposal after site walkdown
- On-site throughout the project
- All hardware sourcing coordinated
- Full documentation at completion
Tell Us About Your Project
We respond same day.
Ready to Get Started?
Fixed-price proposal. On-site Southern California. Call or submit the form — we respond same day.