SLC-500 to ControlLogix Migration
Carson
Rockwell discontinued the SLC-500 in 2023. Carson’s manufacturing, chemical processing, and distribution facilities run a significant share of their production on aging SLC-500 systems. Direct Source handles the complete migration — program conversion, I/O mapping, panel work, startup, and documentation — on-site in Carson.
On-site Carson
Studio 5000 certified
Request a Quote
Same-day response. Describe your project — we’ll schedule a walkdown and deliver a fixed-price proposal.
The Project
SLC-500 to ControlLogix Migration — Carson
Direct Source migrates Allen-Bradley SLC-500 systems to ControlLogix and CompactLogix for industrial facilities across Carson (Carson, Torrance, Gardena, Compton). We handle the complete project: program analysis and conversion, I/O mapping, hardware selection, panel modification or replacement, startup, commissioning, and as-built documentation. Fixed-price proposals after a site walkdown.
Program Analysis & Conversion
We analyze your existing SLC-500 program, document all I/O, timers, counters, and subroutines, then convert to Studio 5000 for ControlLogix or CompactLogix. On-site in Carson for all phases.
We review every converted rung before startup — no automated tool and walk away.
I/O Mapping & Hardware Selection
Full I/O audit of your SLC-500 chassis, card-by-card documentation, and hardware selection for the replacement platform matched to your I/O count and panel footprint.
We specify exactly what hardware you need and coordinate procurement.
Panel Modification or Replacement
Existing panel modified to accept new ControlLogix hardware, or replacement panel built. New backplane, power supply, processor, and I/O cards wired to existing field wiring where possible.
Reusing field wiring saves significant labor cost on most SLC-500 migrations.
Startup & Commissioning
Step-by-step startup at your Carson facility: I/O checkout, sequence testing, HMI reconnection, and production verification. We stay through confirmed production.
Full startup records and documentation delivered at project completion.
HMI Migration
RSView32 and PanelView Classic HMI migration to FactoryTalk View ME/SE or PanelView Plus. Tag remapping, screen rebuild, and communication reconfiguration for the new platform.
Screen layouts stay familiar for your operators wherever possible.
As-Built Documentation
Complete documentation package: panel drawings, I/O list, program printout, hardware list, network configuration, and startup checklist.
Documentation is included in every migration project.
Why Direct Source
What Makes Our Approach Different
On-site throughout Carson
We are on-site for every phase — site walkdown, hardware staging, installation, startup, and commissioning. No remote-only handoffs.
Fixed-price migration scope
We scope SLC-500 migrations as fixed-price projects. You know the full cost before approving. No open-ended hourly billing.
Minimal production downtime
Program conversion, hardware staging, and panel pre-wiring complete before cutover. Cutover happens in the planned shift.
Carson coverage
Direct Source serves Carson, Torrance, Gardena, Compton and surrounding South Bay / LA cities for SLC-500 migration projects.
Every Project Includes
- Site walkdown before proposal
- Fixed-price project proposal
- Hardware specification & procurement
- On-site installation and startup
- As-built documentation package
- Post-startup support
Serving: Carson, Torrance, Gardena, Compton and surrounding cities.
FAQ
Frequently Asked Questions
Why migrate our SLC-500 now?
Rockwell discontinued the SLC-500 in 2023. No new hardware is manufactured. Spare processors, power supplies, and I/O cards come from depleting secondary market stock. One failed component can mean weeks of downtime. Migration to ControlLogix eliminates that risk.
How long does the migration take?
Most single-processor SLC-500 migrations take 4–8 weeks from project start to production startup: 1–2 weeks for program analysis and conversion, 1–2 weeks for hardware procurement and panel work, and 1–2 weeks for startup.
Can you reuse our existing field wiring?
Usually yes. Most SLC-500 I/O cards use terminal block wiring that can be reconnected to new ControlLogix I/O cards. We document existing wiring during analysis and design the new hardware to match — this significantly reduces installation labor.
Do you migrate the HMI at the same time?
We recommend migrating both at the same time. RSView32 and PanelView Classic HMIs do not communicate with ControlLogix the same way, and they are also end-of-life. Including HMI migration avoids a second cutover.
What does SLC-500 migration cost in Carson?
SLC-500 migrations typically range from $30,000 to $150,000 depending on I/O count, number of processors, HMI scope, and panel modification required. We provide fixed-price proposals after a site walkdown.
Get Started
Request a Project Quote
- Fixed-price proposal after site walkdown
- On-site throughout the project
- All hardware sourcing coordinated
- Full documentation at completion
Tell Us About Your Project
We respond same day.
Ready to Get Started?
Fixed-price proposal. On-site Carson. Call or submit the form — we respond same day.